MEP Scan to BIM Services

The services your building runs on; every pipe, duct and cable run modelled exactly as installed, in the spaces where change is most constrained.

Shape Background
0 +

Years of Experience

0 K+

Successful Projects

0 +

Countries Served

0 +

Happy Clients

MEP SCAN TO BIM

The Service That Needs the Most Accurate Model

The services that heat, cool, power and supply a building run through spaces that are often the most constrained, congested and the hardest to survey by hand. Ceiling voids packed with overlapping duct runs, pipe routes that change direction without documentation. None of this is easy to measure with a tape measure and a clipboard.

Laser scanning changes that entirely. It is uniquely suited to MEP surveys because it works in the same environments where manual survey falls short. The resulting point cloud becomes the basis for a model your engineers can actually rely on.

Scan to BIM produces MEP BIM models directly from your point cloud data, covering all three engineering disciplines (mechanical, electrical and plumbing) in a single co-ordinated workflow. Every element is modelled as a parametric Revit element with verified routing, sizing and spatial co-ordinates, ready for retrofit design, clash detection, or FM asset management.

01 Up to LOD 500 Output Levels
02 M · E · P All Three Disciplines
03 ISO 19650 Aligned Workflows
04 COBie Ready FM Asset Data on Request
WHEN DO YOU NEED THIS?

Six Project Triggers

An MEP BIM model becomes essential at each of these project stages.

Common Icon

Retrofit & Decarbonisation

Energy engineers needing an accurate existing services model as the verified base for HVAC or electrical retrofit design.

Common Icon

Congested Void Surveys

Project teams needing spatial data from congested ceiling voids before routing new services through occupied or constrained buildings.

Common Icon

Healthcare & Clean Rooms

Facilities teams requiring precise existing service models for healthcare, laboratory or cleanroom environments.

Common Icon

FM & Asset Management

Facilities managers building an as-installed MEP model tagged with asset data for planned maintenance and CAFM integration.

Common Icon

MEP Co-ordination Backdrop

BIM co-ordinators needing verified existing services geometry as the backdrop for new MEP design co-ordination and clash detection.

Common Icon

Condition & Services Survey

Building owners or engineers documenting existing services condition and routing for dilapidations, lease or compliance purposes.

WHY IT MATTERS

MEP Scan to BIM vs. Manual Building Services Survey

Here is what changes when your MEP model is built from scan data rather than a manual services survey.

Manual Building Services Survey
MEP Scan to BIM
✗

Manual surveys require access to ceiling voids, risers and plant rooms, which is often disruptive in occupied buildings.

✓

Every service visible in the point cloud is modelled across all scanned zones.

✗

Pipe and duct sizes estimated visually. Accurate dimensioning requires direct measurement.

✓

All element dimensions traced from verified millimetre-accurate scan geometry; no estimation required.

✗

Routing paths approximated. Accurate co-ordinates for above-ceiling runs rarely achieved.

✓

Exact routing paths, invert levels and spatial co-ordinates are modelled for every service in the scan.

✗

Produces 2D schematic drawings that cannot be used for co-ordination or scheduling in a BIM environment.

✓

Produces parametric BIM model. Schedules, clash checks and CAFM integration all built in.

✗

Difficult to record service congestion accurately; visual diagrams don't convey spatial density.

✓

Exact congestion geometry modelled. This is critical for routing new services through constrained voids.

FULL DELIVERABLE SCHEDULE

What You Receive

Scope, disciplines and LOD are confirmed at start. Every element is QA-reviewed against the source scan before issue.

Deliverable Scope & Detail
Mechanical (HVAC) Model Ductwork, AHUs, FCUs, VAV boxes, diffusers, grilles and mechanical plant modelled with verified sizes, routing and connection points.
Electrical Model Cable trays, trunking, conduit, distribution boards, LV panels and busbar systems modelled with routing and spatial co-ordinates.
Plumbing & Drainage Model Pipework across hot, cold, heating and chilled water systems (valves, tanks, pumps, sanitary ware and drainage), as installed.
Ceiling Void & Riser Model Above-ceiling and riser zone services modelled to the exact congestion geometry shown in the scan. This is critical for routing new services without clashes.
Central & Distributed Plant Boilers, chillers, cooling towers, pumps and roof plant modelled with connection positions and spatial footprints.
MEP Clash Detection Report MEP model checked against architectural and structural models in Navisworks, clashes flagged with location and priority.
COBie Asset Data Equipment tagged with manufacturer, model, install date and maintenance interval for CAFM integration at LOD 400 on request.
Issue Formats Native Revit .rvt, IFC 2x3 or IFC 4, Navisworks .nwc, version-matched, with MEP content schedule and transmittal.
OUTPUT SPECIFICATIONS

Level of Detail | Up to LOD 500

We confirm the required LOD at the scope stage. Most retrofit and FM projects specify LOD 350 or 400.

LOD 300

300
  • Approximate service routing
  • Plant positions and approximate sizes
  • Discipline-level spatial co-ordinates

Right Arrow For: scoping, early retrofit design

LOD 350

350
  • Accurate routing with invert levels
  • Connection points and interfaces shown
  • Clash-detection-ready with other disciplines

Right Arrow For: co-ordination, retrofit engineering

LOD 400

400
  • Full component geometry and sizing
  • COBie parameters on all equipment
  • FM-ready asset data throughout

Right Arrow For: FM, CAFM, healthcare, decarbonisation

Level of Detail
FIVE-STAGE WORKFLOW

How It Works

Every project follows a structured five-stage process from scope agreement through to reviewed issue.

Step 01

Scope & MEP Brief

Disciplines, LOD, COBie requirements, CDE naming and individual service priorities confirmed before modelling begins.

Step 02

Scan Data Review

Point cloud registered, cleaned and coverage verified across ceiling voids, risers, plant rooms and service zones in scope.

Step 03

MEP Modelling

Ductwork, pipework, containment and plant built in Revit from verified scan geometry across all three disciplines.

Step 04

Co-ordination & QA Review

Model checked for clashes against architectural and structural models in Navisworks. Two-stage QA: routing accuracy against scan, then COBie data and classification reviewed.

Step 05

Issue & CDE Upload

Model issued as .rvt and IFC with MEP content schedule. COBie export and CDE upload handled where required.

CLIENTS & SECTORS

Who Avails Our MEP Scan to BIM Services

Six client types who regularly commission MEP Scan to BIM.

Shape Design

MEP Engineers & Designers

Verified existing services models as the base for retrofit, extension and new MEP design in existing buildings.

Shape Design

Healthcare & Critical Facilities

Precise existing services models for hospitals, laboratories and clean rooms where accuracy underpins compliance.

Shape Design

Retrofit & Refurbishment Contractors

Accurate as-installed MEP models for construction management and co-ordination in occupied or constrained spaces.

Shape Design

Energy & Decarbonisation Consultants

Existing HVAC and electrical models as the verified base for decarbonisation assessments and Net Zero retrofit.

Shape Design

Facilities Managers

FM-ready MEP models tagged with COBie data for planned maintenance and CAFM integration.

Shape Design

Survey Companies

Extend your deliverable set with production-quality MEP Revit model output from your scan data.

Discuss your Scan to BIM project

Need an accurate MEP model of your building's existing services?

Scan to BIM delivers scan-derived MEP BIM models for engineers, contractors and FM teams.

Contact Us
FAQ
FREQUENTLY ASKED QUESTIONS

Frequently Asked Questions

Our service covers all three MEP disciplines: Mechanical (ductwork, AHUs, HVAC plant and distribution), Electrical (cable trays, trunking, conduit, distribution boards) and Plumbing (pipework, drainage, valves, tanks and sanitary ware). All three are modelled from the same point cloud in a single co-ordinated workflow.

Yes. The scan-derived MEP model is structured for Navisworks or Revit co-ordination environment alongside new design models. Clash detection between existing and proposed services is one of the most common uses of this deliverable.

Yes. All disciplines are modelled from the same point cloud and shared co-ordinates, so they can be federated at any time.

Yes, provided the scan covers them. We model every service that is visible in the point cloud, including dense, overlapping runs. If the void was not scanned, we flag the gap before modelling starts.

LOD is confirmed at the scope stage. LOD 300 suits early scoping and retrofit feasibility. LOD 350 is typical for co-ordination and retrofit engineering. LOD 400 is specified where full COBie asset data and FM-ready parameters are required throughout.

GET IN TOUCH

Start Your Scan to BIM Project

Send us your scan data details, point cloud format and project requirements. We will review your brief, confirm scope and have the right team allocated within 48 hours.

01

NDA Protected

All scan data, project files and client information handled under strict NDA.

02

100% Confidential

Your data stays yours. We guarantee full confidentiality throughout the project.

03

24-Hour Response

Send us your brief today. You’ll hear back from our team within one business day.

GET STARTED

Request a Scan to BIM Quote Today